隔膜压缩机G2系列常用产品型号及基本参数

序号

产品型号

容积流量

进气压力

排气压力

循环水量

曲轴转速

电机功率

外形尺寸

机组重量

Nm³/h

MPa(G)

MPa(G)

L/h

r/min

KW

LXWXH mm

kg

1

GZ2-10/10-150

10

1

15

400

420

4

1400X850X1150

800

2

GZ2-15/13

15

常压

1.3

400

400

4

1400X850X1150

800

3

GZ2-15/13-200

15

1.3

20

400

400

4

1400X850X1150

800

4

GZ2-40/4-30

40

0.4

3

400

400

4

1400X850X1150

800

5

GZ2-20/30-400

20

3

40

400

400

4

1400X850X1150

800

6

GP2-50/4-10

50

0.4

1

400

430

5.5

1400X850X1150

800

7

GZ2-12/160-1000

12

16

100

500

400

5.5

1400X850X1150

800

8

GZ2-120/8-16

120

0.8

1.6

600

450

7.5

1400X850X1150

800

9

GZ2-100/15-80

100

1.5

8

900

430

11

1400X850X1150

900

10

GL2-20/200

20

常压

20

700

400

7.5

1700X850X1150

1100

11

GL2-40/13

40

常压

1.3

700

400

7.5

1700X850X1150

1200

12

GL2-40/13-200

40

1.3

20

700

400

7.5

1700X850X1150

1000

13

GL2-25/1-160

25

0.1

16

1000

400

11

1700X850X1150

1100

14

GL2-40/4-160

40

0.4

16

1000

400

11

1700X850X1150

1050

15

GL2-50/7-160

50

0.7

16

1000

400

11

1700X850X1150

1000

16

GL2-40/7-320

40

0.7

32

1000

420

11

1700X850X1150

900

17

GL2-60/12-160

60

1.2

16

1000

360

11

1700X850X1150

900

18

GL2-40/13-400

40

1.3

40

1000

400

11

1700X850X1150

900

19

GL2-30/4-350

30

0.4

35

1000

420

11

1700X850X1150

900

20

GD2-60/30-400

60

3

40

1000

400

11

1700X850X1150

850

21

GL2-50/5-200

50

0.5

20

1300

450

15

1700X850X1150

900

22

GL2-90/29-220

90

2.9

22

1300

430

15

1700X850X1150

900

23

GL2-52/7.5-455

52

0.75

45.5

1400

450

15

2000X1300X1400

2000

24

GL2-15/350

15

常压

35

1500

400

18.5

1700X1200X1150

1500

25

GL2-55/10-200

55

1

20

1500

430

18.5

1700X1200X1150

1500

26

GL2-60/10-250

60

1

25

1500

400

18.5

1700X1200X1150

1500

27

GL2-200/50-200

200

5

20

1500

450

18.5

1700X1200X1150

1500



压缩机询价须知

Requirements for compressor inquiry

客户订购压缩机或询价时,应提供以下基本参数:

When a customer orders a compressor or an inquiry, the following basic parameters should be provided:

吸气压力

Suction pressure

MPa(G)

吸气温度

Suction temperature

排气压力

Discharge pressure

MPa(G)

压缩机排气温度

Discharge tempreture

冷却后排气温度

Discharge tempreture

After cooling

压缩介质

Medium

容积流量

Volume flow rate

 (标准状态)

(NTP)

(Nm3/h)








备注:
1. 吸气压力:也称入口压力,即买方气源的压力(在不考虑气源至吸气口之间管路的压力损失时);

The suction pressure is also known as the entrance pressure, air pressure (in which the buyer does not consider the loss of pressure pipeline between the gas to the suction port of the gauge or absolute pressure).

2. 吸气温度:也称入口温度,即买方气源的压力(在不考虑气源至吸气口之间管路的温度损失时);

Suction temperature: also known as the inlet temperature, that is, the pressure of the buyer's gas source (when the temperature loss of the pipeline between the gas and the suction ports is not taken into account)

3. 排气压力:也称出口压力,即买方系统所需的zui高工作压力;

Discharge pressure: also known as the outlet pressure, the maximum working pressure required by the buyer's system

4. 压缩机排气温度:也称出口温度,即在压缩机排气口处,气体经压缩后所测量的zui高温度,此温度应小于压缩介质所允许的zui高温度;

Discharge temperature of compressor is also known as outlet temperature, which is the highest temperature measured by compression at the outlet of compressor. This temperature should be smaller than the maximum temperature allowed by compressed medium.

5. 冷却后排气温度:压缩机排气口排出的高温气体经压缩机自身冷却系统冷却后,供买方使用的气体温度;

The Discharge temperature after cooling: the temperature of the gas used by the buyer after the compressor exhaust outlet is cooled by the compressor's own cooling system.

6. 压缩介质(气体):如是混合气体,应提供各种气体的组分及各种组分所占混合气体的比例;

Compressed medium (gas): as a mixture of gases, the components of all kinds of gases and the proportion of various components to the mixture should be provided.
7. 容积流量:也称排气量,即在上述吸气压力、排气压力时单位时间内所需的气体体积,并说明状态;

Volume flow: also known as the volume of exhaust gas, that is, the volume of gas required in unit time at the above suction pressure and discharge pressure, and to explain the state of the gas.

8. 电气的防爆等级、对自控的具体要求及其他特殊要求

Electrical explosion-proof grade, specific requirements for automatic control and other special requirements

9. 是否对材质有特殊要求?是否有循环水冷却?如无,需要配备风冷却器还是冷水机组冷却器

Are there any special requirements for the material? Is there circulating water cooling? If not, air cooler or chiller

10.国外订货时应明确动力电的电压及频率

The voltage and frequency of power electricity should be clearly defined



上一篇:没有了
下一篇:没有了

最近浏览:

相关产品

相关新闻

电话:13910788875/13910099493     邮箱:luokeqin@126.com    生产基地:安徽省芜湖市经济技术开发区万春街道清水河路79号

1595919255766640.png

手机官网

1595919255766640.png

微信客服