欢迎来到中鼎恒盛气体设备(芜湖)有限公司官网!

服务热线

0553-8821203

隔膜压缩机G5
您当前的位置 : 首 页 > 隔膜压缩机 > 隔膜压缩机G5

G5系列隔膜压缩机

2020-09-10 16:49:03
G5系列隔膜压缩机
详细介绍:


隔膜压缩机G5系列常用产品型号及基本参数

序号

产品型号

容积流量

进气压力

排气压力

循环水量

曲轴转速

电机功率

外形尺寸

机组重量

Nm³/h

MPa(G)

MPa(G)

L/h

r/min

KW

LXWXH mm

kg

1

GD5-250/0.3-8

250

0.03

0.8

3800

420

45

4200X2900X1800

14000

2

GD5-4500/185-190

4500

18.5

19

3800

420

45

3800X2600X2500

15000

3

GD5-8000/235-250

8000

23.5

25

3800

429

45

3800X2600X2500

15000

4

GD5-9000/78-83

9000

7.8

8.3

3700

450

45

3800X2600X2500

15000

5

GD5-250/0.3-12

250

0.03

1.2

4700

375

55

4200X2900X1800

14000

6

GD5-500/0.8-10

500

0.08

1

6800

429

75

4400X2850X2200

16000

7

GD5-150/200

150

常压

20

7000

430

90

4400X2850X2200

13000

8

GD5-350/6-220

350

0.6

22

7000

400

90

4400X2850X2200

13000

9

GD5-500/5-50

500

0.5

5

8000

400

90

4000X2600X2100

12000

10

GD5-500/0.7-23

500

0.07

2.3

9500

429

110

4400X2850X2200

14000

11

GD5-550/17-200

550

1.7

20

9500

400

110

3700X2750X2000

10000

12

GD5-500/4.5-200

500

0.45

20

10000

420

132

3800X2700X2000

10800

13

GD5-525/6-200

525

0.6

20

12000

400

132

3800X2700X2000

10800

14

GD5-500/7-200

500

0.7

20

12000

420

132

3800X2700X2000

10800

15

GD5-500/10-200

500

1

20

12000

400

132

3700X2750X2000

10000

16

GD5-750/9.5-220

750

0.95

22

12000

420

132

4000X2850X2100

13000

17

GD5-750/10-200

750

1

20

12000

420

132

4000X2850X2100

13000

18

GD5-800/23-220

800

2.3

22

12000

420

132

4000X2850X2100

13000

19

GD5-800/18-210

800

1.8

21

12000

420

132

4000X2850X2100

13000

20

GD5-1080/5-31.5

1080

0.5

3.15

12000

429

132

4400X2850X2200

14000

21

GD5-600/15-350

600

1.5

35

12800

429

160

4000X2850X2100

12000

22

GD5-800/12.7-240

800

1.27

24

12000

420

160

4000X2850X2100

12000

23

GD5-1000/15-180

1000

1.5

18

15000

420

160

4000X2850X2100

12000

24

GD5-1000/20-180

1000

2

18

12000

420

160

4000X2850X2100

13000

25

GD5-1000/15-210

1000

1.5

21

12000

420

160

4000X2850X2100

13000

26

GD5-1200/19-220

1200

1.9

22

12000

420

160

4000X2850X2100

13000

27

GD5-1200/29.5-250

1200

2.95

25

12000

420

160

4000X2850X2100

13000

28

GD5-1300/45-220

1300

4.5

22

13500

429

160

4000X2900X2450

16000

29

GD5-2900/45-120

2900

4.5

12

13200

429

160

4000X2900X2450

16000

30

GD5-1230/3.5-33.5

1230

0.35

3.35

16000

420

185

4200X2900X1800

16000



压缩机询价须知

Requirements for compressor inquiry

客户订购压缩机或询价时,应提供以下基本参数:

When a customer orders a compressor or an inquiry, the following basic parameters should be provided:

吸气压力

Suction pressure

MPa(G)

吸气温度

Suction temperature

排气压力

Discharge pressure

MPa(G)

压缩机排气温度

Discharge tempreture

冷却后排气温度

Discharge tempreture

After cooling

压缩介质

Medium

容积流量

Volume flow rate

 (标准状态)

(NTP)

(Nm3/h)








备注:
1. 吸气压力:也称入口压力,即买方气源的压力(在不考虑气源至吸气口之间管路的压力损失时);

The suction pressure is also known as the entrance pressure, air pressure (in which the buyer does not consider the loss of pressure pipeline between the gas to the suction port of the gauge or absolute pressure).

2. 吸气温度:也称入口温度,即买方气源的压力(在不考虑气源至吸气口之间管路的温度损失时);

Suction temperature: also known as the inlet temperature, that is, the pressure of the buyer's gas source (when the temperature loss of the pipeline between the gas and the suction ports is not taken into account)

3. 排气压力:也称出口压力,即买方系统所需的zui高工作压力;

Discharge pressure: also known as the outlet pressure, the maximum working pressure required by the buyer's system

4. 压缩机排气温度:也称出口温度,即在压缩机排气口处,气体经压缩后所测量的zui高温度,此温度应小于压缩介质所允许的zui高温度;

Discharge temperature of compressor is also known as outlet temperature, which is the highest temperature measured by compression at the outlet of compressor. This temperature should be smaller than the maximum temperature allowed by compressed medium.

5. 冷却后排气温度:压缩机排气口排出的高温气体经压缩机自身冷却系统冷却后,供买方使用的气体温度;

The Discharge temperature after cooling: the temperature of the gas used by the buyer after the compressor exhaust outlet is cooled by the compressor's own cooling system.

6. 压缩介质(气体):如是混合气体,应提供各种气体的组分及各种组分所占混合气体的比例;

Compressed medium (gas): as a mixture of gases, the components of all kinds of gases and the proportion of various components to the mixture should be provided.
7. 容积流量:也称排气量,即在上述吸气压力、排气压力时单位时间内所需的气体体积,并说明状态;

Volume flow: also known as the volume of exhaust gas, that is, the volume of gas required in unit time at the above suction pressure and discharge pressure, and to explain the state of the gas.

8. 电气的防爆等级、对自控的具体要求及其他特殊要求

Electrical explosion-proof grade, specific requirements for automatic control and other special requirements

9. 是否对材质有特殊要求?是否有循环水冷却?如无,需要配备风冷却器还是冷水机组冷却器

Are there any special requirements for the material? Is there circulating water cooling? If not, air cooler or chiller

10.国外订货时应明确动力电的电压及频率

The voltage and frequency of power electricity should be clearly defined



上一篇:没有了
下一篇:没有了

最近浏览:

相关产品

相关新闻

电话:13910788875/13910099493     邮箱:luokeqin@126.com    生产基地:安徽省芜湖市经济技术开发区万春街道清水河路79号

1595919255766640.png

手机官网

1595919255766640.png

微信客服